GRID-TIE INVERTERS
GT Series Grid Tie Solar Inverters - 60 Hz Models
The Xantrex Grid Tie Solar Inverter (GT Series) is designed to convert photovoltaic (PV) electricity produced by solar modules into utility-grade power that can be used by the home or sold to the local electrical utility. Offering high efficiency (up to 96.0 %), clean aesthetics, high reliability, and a low installed cost, through ease of installation and integrated features, the GT Series is a proven, high-frequency design in a compact enclosure. The GT Series may be installed as a single inverter, for a single PV array, or in a multiple-inverter configuration for large PV arrays.
Technology Installation Performance Serviceability
Specifications Specifications are subject to change without notice
GT5.0
GT4.0N
GT3.8
GT3.3N
GT2.8
Output
240 V
208 V
240 V
208 V
240 V
208 V
240 V
208 V
240 V
208 V
Max. AC power output
5000 W
4500 W
4000 W
3800 W
3800 W
3500 W
3300 W
3100 W
2800 W
2700 W
AC output voltage (nominal)
240 V
208 V
240 V
208 V
240 V
208 V
240 V
208 V
240 V
208 V
AC output voltage range
211-264 Vac
183-229 Vac
AC frequency (nominal)
60 Hz
AC frequency range
59.3 - 60.5 Hz
Startup current
0 Aac
Max. continuous output current
21 A
22 A
16.7 A
18.3 A
15.8 A
16.8 A
13.8 A
14.9 A
11.7 A
13.0 A
Max. output over-current protection
30 A
25 A
20 A
25 A
20 A
15 A
Max. utility backfeed current
O A
Total harmonic distortion (THD)
< 3 %
Power factor
> 0.99 % (at rated power), > 0.95 % (full power range)
Utility monitoring, islanding protection
UL1741-2005 / IEEE 1547
Output characteristics
Current Source
Output current waveform
True sine wave
Max. array open-circuit voltage
600 Vdc
MPPT voltage range (CEC & CSA)
240 - 550 Vdc
240 - 480 Vdc
195 - 550 Vdc
200 - 400 Vdc
195 - 550 Vdc
MPPT operating range
235 - 550 Vdc
235 Vdc - 550 Vdc
195 Vdc - 550 Vdc
200 Vdc - 550 Vdc
193 Vdc - 550 Vdc
Max. input current
22.0 Adc
20.0 Adc
18.0 Adc
17.0 Adc
20.8 Adc
19.5 Adc
17.5 Adc
16.5 Adc
15.4 Adc
14.9 Adc
Max. array short-circuit current
24.0 Adc
Reverse-polarity protection
Short-circuit diode
Ground-fault protection
GF detection, IDIF > 1 A
Max. inverter efficiency
95.9%
95.5%
96.0%
95.7%
95.9%
95.6%
95.9%
95.6%
95.0%
94.6%
CEC efficiency
95.5%
95.0%
95.5%
95.0%
95.0%
95.0%
95.5%
95.0%
94.0%
93.5%
Night-time power consumption
1 W
Operating temperature range
-13°F to +149°F (-25°C to +65°C)
Enclosure type
NEMA 3R (outdoor rated)
Inverter weight
58.0 lb (25.8 kg)
58.0 lb (25.8 kg)
58.0 lb (25.8 kg)
49.0 lb (22.2 kg)
49.0 lb (22.2 kg)
Shipping weight
65.0 lb (27.2 kg)
65.0 lb (27.2 kg)
65.0 lb (27.2 kg)
57.0 lb (25.9 kg)
57.0 lb (25.9 kg)
Inverter dimensions (H x W x D)
28 1/2 x 16 x 5 3/4” (724 x 403 x 145 mm)
Shipping dimensions (H x W x D)
34 x 20 1/2 x 10 5/16” (866 x 518 x 262 mm)
Mounting
Wall mount (mounting bracket included)
Input and output terminal
AC and DC terminals accept wires sizes of #14 to #6 AWG
PV / Utility disconnect
Eliminates need for external PV (DC) disconnect. Complies with NEC requirements
Cooling
Convection cooled, fan not required
Display
Backlit, two-line, 16-character liquid crystal display provides instantaneous power, daily and lifetime energy production, PV array voltage and current, utility voltage and frequency, time online “selling”, fault messages, and installer-customizable screens
Communications
Integrated RS232 and Xanbus™ RJ45 communication ports
Wiring box
PV, utility, ground, and communications connections. The inverter can be separated from the wiring box.
Warranty
10-year standard
Model name (negative ground)
GT5.0-NA-240/208 UL-05
GT4.0N-NA-240/208 UL-05
GT3.8-NA-240/208 UL-05
GT3.3N-NA-240/208 UL-05
GT2.8-NA-240/208 UL-05
Part number (negative ground)
864-1009
864-1008
864-1032
864-1006
864-1001
Positive ground inverters are also available
Regulatory
Certified to UL1741 1st Edition: 2005 version CSA 107.1 CSA 2 C22.2 No. 107-1-01 general use power supplies